IC-M87 ATEX
Tough and Waterproof
Simple Operation
Li-Ion Battery for Long Battery Life
22 Programmable Channels for PMR
The ATEX version uses the BP-227AX battery. It provides 22 programmable PMR channels, IPX7 protection and up to 19 hours of operation at a 5:5:90 TX/RX/standby duty cycle.
Hazardous-area use requires BP-227AX and the jack cover or HM-138. Chargers are not intrinsically safe; charge outside hazardous areas.
| Parameter | Marine | PMR |
|---|---|---|
| TX frequency | 156.000–161.450 MHz | 146.000–174.000 MHz |
| RX frequency | 156.000–163.425 MHz | 146.000–174.000 MHz |
| Groups / channels | INT, USA (version-dependent) | 22 PMR channels |
| Type of emission | 16K0G3E | 16K0F3E/8K50F3E; 14K0F3E/8K50F3E |
| Channel spacing | 25 kHz | 12.5/25 kHz; 20/25 kHz |
| Power supply | 7.4 V DC nominal | 7.4 V DC nominal |
| TX current (1 W) | 0.7 A typ. | 0.7 A typ. |
| RX current (max. audio) | 200 mA typ. | 200 mA typ. |
| Antenna impedance | 50 Ω, SMA | 50 Ω, SMA |
| Operating temperature | −15°C to +55°C | −25°C to +55°C |
| Dimensions with BP-227AX | 62 × 97 × 39 mm | 62 × 97 × 39 mm |
| Weight with BP-227AX | 280 g | 280 g |
| Output power (7.2 V DC) | 1 / 0.5 W | 1 W |
| Max. frequency deviation | ±5.0 kHz | ±5.0 / ±4.0 / ±2.5 kHz (W/M/N) |
| Frequency stability | ±1.5 kHz | ±1.5 kHz |
| Spurious emissions | 0.25 μW (≤2 GHz); 1.0 μW (>2 GHz) | 0.25 μW (≤2 GHz); 1.0 μW (>2 GHz) |
| Residual modulation | 40 dB | 40 / 34 dB (W/N) |
| Audio harmonic distortion | <10% (at 60% deviation) | <10% (at 60% deviation) |
| Modulation limiting | 60–100% of maximum deviation | 60–100% of maximum deviation |
| Sensitivity (20 dB SINAD) | −2 dBμ typ. (emf) | −4 dBμ typ. (emf) |
| Adjacent channel selectivity | 70 dB | 70 / 60 dB (W/N) |
| Spurious response | 70 dB | 70 dB |
| Intermodulation | 68 dB | 65 dB |
| Hum and noise | 40 dB | 40 / 34 dB (W/N) |
| Audio output (10%, 8 Ω) | 200 mW | 350 mW |
| Ingress protection | IPX7 | IPX7 |
| Rating stated in official brochure | II 2G Ex ib IIA T3 Gb | II 2G Ex ib IIA T3 Gb |
| ATEX ambient temperature | −20°C to +55°C | −20°C to +55°C |
The ATEX version requires BP-227AX and the jack cover or HM-138. Operating-temperature specifications do not override the certified ATEX ambient-temperature limits. Chargers are not intrinsically safe and must not be used in explosive atmospheres.
Supplied accessories
BP-227AX · BC-152N · BC-147SE (version-dependent) · MB-86 · FA-S59V · Hand strap
MIL-STD-810F
| Test | Method | Procedure |
|---|---|---|
| Low pressure | 500.4 | I, II |
| High temperature | 501.4 | I, II |
| Low temperature | 502.4 | I, II |
| Temperature shock | 503.4 | I-C |
| Solar radiation | 505.4 | I |
| Rain blowing/drip | 506.4 | I, III |
| Humidity | 507.4 | — |
| Salt fog | 509.4 | — |
| Vibration | 514.5 | I |
| Shock | 516.5 | I, IV |
Equivalent MIL-STD-810-C, -D and -E. Measurements: EN 301-178 / EN 300 086.
Optional Accessories
HM-138 · BP-227AX · BC-152N · BC-147S · BC-121N + AD-100 · BC-157S · MB-98 · MB-86 · MB-96F
Use in an ATEX hazardous area: Icom requires the BP-227AX battery and either the connector cover or the HM-138 speaker-microphone. Charging is permitted only outside the hazardous area.